Alibaba.com

Verified Supplier | Dandong Aolong Radia...

Dandong Aolong Radiative Instrument Group Co., Ltd.

China (Mainland) | Manufacturer, Trading Company | Contact Details
Experience:
Established 2003
10 years OEM
Performance:
Response Rate
Company Feedback

Quick Details

  • Place of Origin: Liaoning, China (Mainland)
  • Brand Name: Aolong
  • Model Number: XYD-4010/3
  • Power: Electronic
  • Usage: NDT fields
  • Brand: Aolong
  • Nature: X-ray
  • Turnover: USD15,000,000
  • Time of establishment: 1964 year
  • Business: Manufacturer
  • Staff: More than 200 people
  • Address: China
  • After-sale services: Better and faster
  • Company: Dandong Aolong Radiative Instrument Co.,Ltd
  • FAX: 86-415-6278889

Packaging & Delivery

Packaging Details: with the international packing standard and requirement of respectful customers
Delivery Detail: within 5 working days

Specifications

1.Stationary x-ray equipment has widely using fields
2. has got two national patents;
3.from 0.1-99.8 minutes

Mobile Constant Potential X-ray flaw Detectors Technological Scheme

(Stationary X-ray equipment XYD-4010/3 model 

 

1.The Summarize

Mobile industrial X-ray flaw detectors is main NDT equipment,Its main function is happen constant potential x-ray, control and adjust and  it,may detect the inside defection of workpiece via radiography

2.Composing

1) Metal ceramic X-ray tube       MXR-400/25    1Pcs    made by COMET

2) High Voltage cable                 225KV 5m        2Pcs     made by COMET.

3) High Voltage generator            T1016            2Pcs    made by ALRC

4) Controller                                 T6000             1Pcs     made by ALRC

5) Oil cooling system                    YLB-2            1Pcs     made by ALRC

6) device for the x-ray tube moving and fixing     1Pcs     made by ALRC

7) Low Voltage cable and the water pipe             1Set     made by ALRC

8) Spare parts                                                     1Set      made by ALRC

 

3.The Main Technical Parameter

3.1 Industrial Unipolar metal Ceramic X-ray tube, made in Switzerland Comet

3.2 Tube voltage:~300KV,  adjust constantly and the step is 1Kv

3.3 Tube current:0.1~10mA(big focus)  0.1~3mA(small focus)

Adjust constantly and the step is 0.1 mA

3.4 The focus size:d=5.5mm(big focus)  d=3.0mm(small focus) (EN12543)

4.0×4.0 (big focus)   1.5×1.5mm(small focus)(IEC336)

3.5 Cooling mode: Oil cooling    minimum oil flow >22L/min

3.6 Radiation coverage:40°

3.7 Exposure condition:

Tube voltage: 300KV  

Tube current: 10mA

Double foil lead intensifying screen

Focus distance: 600mm

Exposure time:10min

 Industrial X-ray film

3.8 Maximal penetration (Fe):70mm

3.9 Sensitivity: ≤ 1.5%  

3.10 Film density: >1.5

3.11 160KV H.V cable:2Pcs,5m/Pcs,adopt flange to connect

3.12 YLB-2 model oil cooling system

Oil cooling system uses imported pump, there are oil flow- rate relay protection switch and oil temperature protection switch inside. When oil flow rate <22L/min , flow- rate switch begins to work, and the x-ray equipment will enter into protection mode, the controller shows the error warning .

3.13 T1016 model H.V Generator

It consists of cathode high-voltage generator and anode high-voltage generator, each of them can output 160KV constant potential high-voltage. make output   allowance to make sure the stability and the  security, it adopt  high quality insulated oil and  a double-voltage rectification circuit is adopted in the generator; together with the filament transformer make the x-ray tube producing  0.1–30 mA tube current.                                         

3.14 T6000 model Controller

Tube voltage: precision ±1%,repetitiveness superior ±1.5%, step≤1KV, actual tube voltage 40-300KV continuous adjust, steady voltage automatically.

Tube current: precision ±1%,repetitiveness superior ±1%, step≤0.1mA, actual tube current 1-10mA continuous adjust, steady current automatically.

T6000 Controller is adopted  PLC control program which is the most advanced in the world at present, 5.7''big screen back light display board, Chinese interface, man-machine dialogue, dynamic display pattern, beautiful design, membrane switch, smooth surface display, easy to operate.

Controller screen displays current working parameters in digital mode, and all function parameters displayed on it can inter-lock diagnostic result.

The controller makes alarm in sound and light signals when the high voltage on and off. It also has the functions of safe interlock protect and alarm when water and electric conditions are not satisfied or in case wrong operations.

The controller has the functions of automatic warm-up, training and presetting the tube current and tube voltage. It makes the tube intelligent training automatically possible.

There are two operation modes, manual and automatic. The parameters of tube voltage, tube current, time preset, focus selection, inter-lock protect, man-machine dialogue and Chinese operation system are make sure no mistake operation. And the high voltage time accumulation, exposure fault memory, figures, sound and alarm prompt all are available.

It adopts high quality and advanced electronic parts. It has setting of many protect functions, system anti-interference abilities and error diagnose display function.

T6000 Controller can achieve the following functions:     

--Control command sending such as high voltage on or off, etc.

--Training automatically control: It can identify whether it should execute training program. It can also cancel the function of training automatically.

--Identify faults and protect automatically: such as undercurrent, over-current, over-voltage, cooling problems, current protect, temperature protect etc.

--Timing or no-timing functions, 0-99minutes including no-timing mode

--The protect function of x-ray tube current and tube voltage up-limited through hardware setting and software setting.

3.15 Device for the X-ray tube moving and fixing

The device uses power-driven control, could make the X-ray tube moves up and down , horizontally and rotationally. Up-down lift distance is 500-1800mm. The user could choose the best state of the tested parts according to the need of the testing, it ensures the distance between

The tube center and the ground ≤500mm .

Buyer Product Name Price Quantity Order Time(GMT+8)
Email to this supplier
Verified Supplier - Dandong Aolong Radiative Instrument Group Co., Ltd.
China (Mainland) | Manufacturer, Trading Company | Contact Details
Experience:
Established 2003
10 years OEM
Performance:
Response Rate
Company Feedback

Communicate with Supplier

Mr. Charles Feng
What can I do for you?
Minisite Survey